In the case you have above the installer wasn't reading his foam. They must be trained to do that as they spray. Temps and conditions are constantly changing thru out the day. Either he wasn't properly trained or if he was,he wasn't doing his job! This is a serious problem with people jumping in to the foam business. A lot of homeowners and builders are looking the best price and end up with someone who doesn't know what they are doing. Hope this info helps. Foam insulation is a great product. It just has to be done right by someone who knows what they are doing.
Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else.  https://www.youtube.com/v/ggLAUsiuI_o&feature=share
One of the high-tech insulation products being utilized these days is a foam-spray product called "Icynene," which is a foam that starts as two liquid components (a and b, if you will) that are heated up and sent through two hoses and meet at a tip of a gun where the magic begins. This is a thin film that expands to 100 times its volume in eight seconds, when it's permanently set up.

Spray Foam Exterior Walls


We carry a full line-up of the best roof coatings and roof waterproofing products - all tested in extreme climates. Our lines include both high-performance and cost-effective solutions. RoofMate HT is a high performance Elastomeric Roof Sealant for light traffic areas. Lucas 6000 universal is a superior high performance top coating. SilverWhite aluminized metal roof coating for metal roofs helps prevent rust. Roof Mate from United Coating has formulas for all type of roofs and  warranties available for up to 15 years. NovaTuff 2-part flexible epoxy systems are top-of-the-line waterproofing grade roof coatings with extremen chemical and salt resistance. For a cost effective quality foam roof recoat, we recommend UltraShield acrylic elastomeric roof coating. UltraShield is available in popular earth-tone colors and in 55G drums.

Spray Foam Insulation Near Me


I used this product to seal and insulate my rim joists as I am finishing the basement. The builder used R13 batt insulation when we built the house 3 years ago. I use a dehumidifier to control moisture in the basement which is below grade. The setting I use is 55%. The dehumidifier kicks on periodically and requires emptying every few days. Since using the foam all around the house on the rim joists and sill plate, the dehumidifier has stayed at 50% for over two weeks since spraying and rarely turns on anymore. I also put the original R13 batt insulation back up after the foam cured.

If you’re not familiar, spray foam is a type of insulation that expands after you spray. The foam expands and seals, avoiding any type of unnecessary moisture (which can create mold) or encouraging pests to eat through your walls. It protects the lining of your house, and even can protect the heating and cooling of your house during those unbearably cold or hot days. https://www.youtube.com/v/ggLAUsiuI_o
While the R value will vary, most ocSPF products have an R value of around 3.8 per inch. Unlike medium-density closed-cell SPF, ocSPF is not a vapour barrier. When installed at 5.5 inches or more, ocSPF does act as an air barrier. It is often used for interior walls because it provides sound reduction by blocking and absorbing air leakage. It is usually only recommended for indoor applications. https://m.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.

In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides).
Access Panels Adhesives, Backer Rod, Brads, Butyl Rubber, Caulk & Sealants, Caulk Guns, Caulking Gun Accessories, Caulk Gun, Bulk, Chem Curbs, Chinking, Coil Roofing Nails, Concrete Anchors, Concrete Products, Concrete Repair, Concrete Stain & Sealer, Confined Space Rescue, Deck Coatings, Deck Hardware, Diamond Saw Blades, Drains, Drains-Balcony>Drain-Balcony, Drain Downspouts / Nozzles, Roof Drain Domes, Drains New-Roof, Drains-Retrofit / Reroof, Electric Hot Air Welders, Electric Service Flashings, EPDM Accessories, Eternabond, Expansion Joints, Fall Protection Kits, Fasteners, Fire Stopping Vents, Flashing Tape, Foam Roofing, Gas & Safety Cans, Generators, Grouts, Hidden, Deck Fasteners, Hot Dipped Roofing Nails, Hot Tar Kettles, Houseboat Roof/Deck Repair, Knowledgebase, Log Home Products, Lead Pipe Flashings, Lead Sheet, Lifelines- Retractables, Magnetic Hammers, Metal Roofing, Miami-Dade Nails, Mortars, Narrow Crown Stainless, Staples, NP1, Polyurethane Foam, Pipe Flashings, Pipe Supports, Power Tools & Accessories, Propane Hot Air Welders, Propane Regulators, Propane Torches, PVC Roofing, Retrofit Pipe Flashings, Rex Synfelt, Rigging/Lifting Hardware, Rivets, Rivets- Stainless, Roof Anchors, Roof Equipment Hatch, Roof Smoke Vents, Roof Hatch, Roof Leak Repair, Roof Paints & Coatings, Roof Repair Materials, Roof Screws, Roofing Fasteners, Roofing Nails, Rooftop Electrical Flashings, Rope, RV & Trailer Roof Repair, RV Roof Replacement, Safety Rail Systems, Saw Blades, Sealants, Sealing Washers, Snow Guards, Spray Polyurethane Foam, Stinger, Stainless Nails/Fasteners, Tarps, TPO Accessories, Underlayments, Vents, Roof Vents, Video Movies, Waterproofing Products, Window Flashing Tape, Wood Deck Hardware, Zinc Sheet https://m.youtube.com/embed/ggLAUsiuI_o
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)
I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.
Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting. https://www.youtube.com/embed/ggLAUsiuI_o

This tropic heat actually is the cause that the steel structure, which most roofs in that part of the world are built on, expands and contracts all the time. By doing so, the sun-battered steel structure causes the roof tiles to dislodge and slowly creates small openings between the roof tiles, through which rain water can run into, creating leaks that can cause much damage to plastered ceilings and electric wiring.
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.

The RV roof coating is a sealing, weatherproofing and waterproofing product that is used in recreational vehicles, campers and trailers, to name some. It works effectively in sealing the roof’s membrane from water and moisture that would otherwise build up and cause damage to the roof. When unattended, the buildup can eventually leads to leaks inside the RV, causing so much discomfort to your loved ones.

Spray Foam Polyurethane


The RV roof coating is a sealing, weatherproofing and waterproofing product that is used in recreational vehicles, campers and trailers, to name some. It works effectively in sealing the roof’s membrane from water and moisture that would otherwise build up and cause damage to the roof. When unattended, the buildup can eventually leads to leaks inside the RV, causing so much discomfort to your loved ones.
In addition, it's difficult for an inexperienced installer to evenly spread the insulation foam over a surface. Miissing spots can leave holes and gaps for cold air to get through. Proceed with this project yourself only if you're doing a small insulation project -- such as installing foam in a crawl space or around your plumbing. Leave larger projects like the attic, basement or garage to the professional insulation contractors. Insulation professionals have the tools, equipment and background knowledge necessary. Moreover, they know how to accurately price insulation, whereas you could inaccurately budget for a DIY project and end up paying significantly more. Don't take the medical, physical or financial risks that come with pursuing this as a DIY project unless you're absolutely certain you have the skills. https://youtube.com/v/ggLAUsiuI_o
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.
As mentioned above, These coatings can work with almost any roof type. Another advantage is they are long-lasting. The coatings are resistant to fungi and mildew among other common materials that damage roofs with time. Another advantage of the coatings is that they are seamless, providing a neat uniform coating. Elastomeric coatings offer individual benefits to certain roof types. For instance, polyurethane foam roofing benefits greatly from the coatings by getting great ozone and UV light protection. The heat reflexive properties also offer great benefits such as lowering cooling costs. This advantage is enjoyed regardless of the rooftype. The heat reflexive properties also offer anti-aging properties when coatings reflect harsh sun rays which age roofs with time. Elastomeric roof coatings are also simple to use, VOC compliant and nontoxic.

How Much Is Spray Foam Per Sq Ft


I recently did a remodel project for my basement using spray foam insulation. The original builder has used fiberglass, but I wanted the best insulation i could find. We chose closed cell foam because it blocks moisture from getting into the house. It took one day to install and was fumey for about 3 hours. It was pretty cool watching it being done. It comes out as a liquid and then expands rapidly into a foam. It's quick! Then they took a types of saw to shave it flat with the wall studs so we could then go ahead and drywall.

How Much For Spray Foam Insulation In Attic


Water-based acrylic coatings have more than 30 years of proven performance over a wide range of substrates. It is the coating of choice for metal roofs since it is highly reflective, can be easily tinted and is not extremely slippery when damp. When used with our rust primer, even rusted roofs can be saved. TIP: If you have a metal roof or a low slope roof that doesn't pond water, consider acrylic coatings.
Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14]
I recently did a remodel project for my basement using spray foam insulation. The original builder has used fiberglass, but I wanted the best insulation i could find. We chose closed cell foam because it blocks moisture from getting into the house. It took one day to install and was fumey for about 3 hours. It was pretty cool watching it being done. It comes out as a liquid and then expands rapidly into a foam. It's quick! Then they took a types of saw to shave it flat with the wall studs so we could then go ahead and drywall.
Access Panels Adhesives, Backer Rod, Brads, Butyl Rubber, Caulk & Sealants, Caulk Guns, Caulking Gun Accessories, Caulk Gun, Bulk, Chem Curbs, Chinking, Coil Roofing Nails, Concrete Anchors, Concrete Products, Concrete Repair, Concrete Stain & Sealer, Confined Space Rescue, Deck Coatings, Deck Hardware, Diamond Saw Blades, Drains, Drains-Balcony>Drain-Balcony, Drain Downspouts / Nozzles, Roof Drain Domes, Drains New-Roof, Drains-Retrofit / Reroof, Electric Hot Air Welders, Electric Service Flashings, EPDM Accessories, Eternabond, Expansion Joints, Fall Protection Kits, Fasteners, Fire Stopping Vents, Flashing Tape, Foam Roofing, Gas & Safety Cans, Generators, Grouts, Hidden, Deck Fasteners, Hot Dipped Roofing Nails, Hot Tar Kettles, Houseboat Roof/Deck Repair, Knowledgebase, Log Home Products, Lead Pipe Flashings, Lead Sheet, Lifelines- Retractables, Magnetic Hammers, Metal Roofing, Miami-Dade Nails, Mortars, Narrow Crown Stainless, Staples, NP1, Polyurethane Foam, Pipe Flashings, Pipe Supports, Power Tools & Accessories, Propane Hot Air Welders, Propane Regulators, Propane Torches, PVC Roofing, Retrofit Pipe Flashings, Rex Synfelt, Rigging/Lifting Hardware, Rivets, Rivets- Stainless, Roof Anchors, Roof Equipment Hatch, Roof Smoke Vents, Roof Hatch, Roof Leak Repair, Roof Paints & Coatings, Roof Repair Materials, Roof Screws, Roofing Fasteners, Roofing Nails, Rooftop Electrical Flashings, Rope, RV & Trailer Roof Repair, RV Roof Replacement, Safety Rail Systems, Saw Blades, Sealants, Sealing Washers, Snow Guards, Spray Polyurethane Foam, Stinger, Stainless Nails/Fasteners, Tarps, TPO Accessories, Underlayments, Vents, Roof Vents, Video Movies, Waterproofing Products, Window Flashing Tape, Wood Deck Hardware, Zinc Sheet https://m.youtube.com/embed/ggLAUsiuI_o

With constant exposure to heat, cold, UV radiation, rain, snow, hail, high winds and possible mechanical damage, a roof can be the most vulnerable component of a building’s exterior. However, a roof’s long-term performance can be enhanced — and major roofing problems avoided — with correct design, quality materials, proper installation and workmanship, and comprehensive care. https://m.youtube.com/watch?v=ggLAUsiuI_o&feature=youtube_gdata
However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]

The roof must be thoroughly cleaned, and allowed to dry thoroughly. This is a critical step to ensure a successful coating application. Be careful not to damage the lap seams. Care should be taken when pressure washing not to disturb the integrity of the underlying roof membrane particularly where there are adhered seams. Refer to the specific coating manufacturer you are using for their specific requirements for roof preparation. http://youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o


Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include: 

Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.
Q. "I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell-spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. It would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing."
The guys who sprayed my attic were trained and certified, but I later found out, too late, that they had no experience and my attic was the first they'd ever sprayed. I was also never told to vacate my house for any length of time, and so I (and my pets) were in the house the day they sprayed and the entire time the off ratio foam was filling my home with horrendous vapors. The company kept telling me that it was a good job and I had nothing to worry about, even after I'd had 2 other experienced sprayers from 2 different companies visually examine the foam and confirm that large areas appeared to be off ratio. The 3rd sprayer from yet another company, was also outraged because the company who did my attic had failed to vacuum up all of the old cellulose insulation, and he also noticed areas where the foam was shrinking or pulling away, and this was not even 5 weeks after the spraying.  
Roof coatings made with acrylics, urethanes or asphalt soften under the stress of ponding water or snowpack. Eventually, these roof coatings will bubble and peel away from the substrate, leaving your roof vulnerable to leaks, rot, and decay. However, GacoRoof’s 100% silicone formulation is designed to stand up to whatever the elements dish out. Silicone will withstand areas of ponding water without softening, bubbling or peeling from the substrate. Acrylic, urethane and asphalt roof coatings decompose and wear away from the stress of harsh sunlight, UV rays, and freeze-thaw cycles.

In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides).
The product is an acrylic coating, which is packed conveniently for ease of use. As it is also in one-gallon size, you can rely on its supreme area coverage reaching up to 125 square feet. The Dicor rubber roof coating is also very easy to apply. When shopping around for a roof coating, we believe it pays off to find an easy to apply product for fast results. It is one of the best qualities of the RV roof coating that makes it a top pick in the category.

How Much For Spray Foam


I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).

c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes . 

How Much Is Spray Foam

×