This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)
Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else.  https://www.youtube.com/v/ggLAUsiuI_o&feature=share
A well-insulated and sealed building envelope can significantly contribute to optimal energy efficiency. As with any project, to fully utilize the benefits of spray foam, attention to detail and proper installation is crucial. It’s important to take appropriate time or seek aid through outside expertise to understand how all types of insulation products can work together within the construction of a home or building and the surrounding environment. When installed correctly, spray foam has the potential to be one of the most effective choices for insulation solutions.
Fill and seal expanding foam sealant is urethane Fill and seal expanding foam sealant is urethane foam designed to fill large areas quickly and permanently. Uses include filling holes cracks or gaps that require a complete airtight and waterproof seal but are too large to be filled with ordinary caulk. The foam expands approximately 3 times its original ...  More + Product Details Close https://m.youtube.com/watch?v=ggLAUsiuI_o
A well-insulated and sealed building envelope can significantly contribute to optimal energy efficiency. As with any project, to fully utilize the benefits of spray foam, attention to detail and proper installation is crucial. It’s important to take appropriate time or seek aid through outside expertise to understand how all types of insulation products can work together within the construction of a home or building and the surrounding environment. When installed correctly, spray foam has the potential to be one of the most effective choices for insulation solutions.
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)
For maximum durability and leak resistance, we recommend that two coats of topcoat be applied at 100 sq. ft. per gallon, or a minimum of 20 mils dry coating. If two complete topcoats are not applied, always apply two thick coats to problem areas such as scuppers, drain areas, ponding areas, seams, and repaired areas. Avoid using Elastek Solar Magic™ or The Shield™ on ponding roofs. Clean skin and tools promptly with water.
Spray foam is available in two different types: open-cell spray foam which is usually $0.44 to $0.65 per board foot and closed-cell spray foam which is about $1 to $1.50 per board foot. The average cost to have spray foam professionally installed is about $2,314. This number can vary depending on whether the home being insulated is newly constructed. However, finished homes are not a good candidate for spray foam insulation but great for weatherization or an energy audit.  
My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :)
We love the Heng’s rubber roof coating because it is versatile enough to work on the RV roof and protects it from the elements longer than other products do. Plus, it is useful enough to be used in sealing seams and tears. Versatility does matter when shopping around for an RV roof coating. It ensures more uses, meaning more value for the money. That said we don’t need to buy a separate product to perform the tasks. https://www.youtube.com/watch?v=ggLAUsiuI_o&feature=youtube_gdata
The process by which heat energy in the form of light (usually IR unless the substrate is hot enough to glow in the visible range) is emitted more strongly by warm surfaces and absorbed by other materials especially those of low IR reflectivity (think matte black finish). Radiant heat transfer does not require a medium. Foam insulation materials, such as spray foam insulation, are opaque to thermal radiation, like most solid materials.
Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating is a high quality flexible white acrylic roof coating. Product is enhanced with silicone for improved water resistance adhesion and life expectancy. Product resists cracking peeling while offering tremendous durability and long term life. The coating forms a durable protective barrier which ...  More + Product Details Close

Spray Foam Sealant


According to the Department of Energy, an estimated 20 to 40 percent of a home’s utility bill could be going to waste from drafts and air leaks around openings. As temperatures cool and energy costs rise, the positive impact of energy efficiency on a building comes into focus. Air can enter and escape a structure through every gap, compromising the building envelope. Adding the right insulation and air-sealing will close these gaps, keeping interior spaces comfortable and reducing energy bills. 

Spray Foam Walls


With constant exposure to heat, cold, UV radiation, rain, snow, hail, high winds and possible mechanical damage, a roof can be the most vulnerable component of a building’s exterior. However, a roof’s long-term performance can be enhanced — and major roofing problems avoided — with correct design, quality materials, proper installation and workmanship, and comprehensive care.
With constant exposure to heat, cold, UV radiation, rain, snow, hail, high winds and possible mechanical damage, a roof can be the most vulnerable component of a building’s exterior. However, a roof’s long-term performance can be enhanced — and major roofing problems avoided — with correct design, quality materials, proper installation and workmanship, and comprehensive care. https://m.youtube.com/watch?v=ggLAUsiuI_o&feature=youtube_gdata
Elastomeric coatings offer effective and affordable solutions for fixing roof leaks. The coatings can be used to repair any type of roof leak. The elastomeric roof coatings can be used throughout the year because they stretch and contract easily to adjust to winter and summer temperatures. It is usually made using polymeric products such as acrylic alongside white pigments like titanium dioxide. This helps create an opaque and reflexive final product.
It also has a great waterproofing ability that can shield the roof’s membrane from water and moisture damage. You can also count on the liquid roof coating for its outstanding performance for a wide range of applications and uses. This product can be used at tears and seams as well as in sealing air conditioners and venting systems and anywhere else where rubberized coating is needed.

How Much Is Spray Foam Insulation


However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]

Polyurethane is a closed-cell foam insulation material that initially contains a low-conductivity gas in its cells.[5] As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch.[5] In comparison, blown fiberglass typically has an R-Value of only R-3 to R-4 per inch.[6]


If you’re not familiar, spray foam is a type of insulation that expands after you spray. The foam expands and seals, avoiding any type of unnecessary moisture (which can create mold) or encouraging pests to eat through your walls. It protects the lining of your house, and even can protect the heating and cooling of your house during those unbearably cold or hot days. https://www.youtube.com/v/ggLAUsiuI_o

Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
Carefully examine the roof membrane (surface material) for cracks, tears, blisters, evidence of ponding, exposed foam, and open seams. If already coated, evaluate the condition of the coating. Pay particular attention to areas around roof penetrations (vents, skylights, pipes, etc), ponding areas, cracks in parapet walls, and the attachment of roof membranes to parapet walls. Roofs should be in good condition to warrant coating.
The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.

Closed-cell spray insulation, a rigid medium-density material, can be used in exterior applications such as continuous insulation applications, as well as interior applications. This type of foam insulation has a higher R-value per inch making it also suitable for small areas that require the highest possible R-value to meet building code requirements. Closed-cell spray foam’s rigidity help reject bulk water making it a recognized flood-resistant material by FEMA.
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)
Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting.

Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include:


Typical roof coating dry film thickness vary from paint film thickness (plus or minus 3 dry mils) to more than 40 dry mils. This means a roof coating actually becomes the top layer of a composite roof membrane and underlying system. As such, the roof coating is the topmost layer of protection for the membrane, receiving the impact of sunlight (both infrared and ultraviolet (UV), rain, hail and physical damage.
Whether you’re sending something fragile in the mail or keeping valuables safe during a move, secure packing is everything. To protect a delicate item, simply fill a spare shopping bag half-full with spray insulation foam and place in the bottom of a box, pressing the item gently into the bag as it hardens to cushion the item. Repeat for the top and you have a DIY custom packaging solution that can handle the rigors of delivery.

Where Can I Buy Spray Foam Insulation Near Me

×