Closed-cell spray insulation, a rigid medium-density material, can be used in exterior applications such as continuous insulation applications, as well as interior applications. This type of foam insulation has a higher R-value per inch making it also suitable for small areas that require the highest possible R-value to meet building code requirements. Closed-cell spray foam’s rigidity help reject bulk water making it a recognized flood-resistant material by FEMA.

To see if ShippingPass is right for you, try a 30-day free trial. Also, with ShippingPass, there is no need to worry about commitment. If you decide you want to discontinue the service, you can cancel your subscription at any time. No matter what your shipping needs, Walmart's got you covered. Sign up for ShippingPass so you can shop more, save money and live better.
A: It can be applied in the similar manner that we apply paint. We can use a paint roller to apply it without any hassle and use of special tools. You can also check the specific manual of instructions from the maker for particular directions. You should also check if it requires single or double coating or the use of a primer before its application.
A. You can use closed-cell spray foam that way if you want, although you should realize that the spray foam will prevent the roof sheathing from drying inward. This approach should only be used if the roof sheathing is bone dry, because it will never dry when sandwiched in this manner. Most building scientists would prefer to see fiberglass rather than closed-cell spray foam under the roof sheathing in this type of assembly.
Allison--would be very interested in your take on the GHG issues of foams, which have received lots of smart commentary recently. To highlight a few: architect Jesse Thompson's comments on Tom's Good vs Bad post on Energy Circle, the very thorough piece by Alex Wilson on Green Building Advisor and Michael Anschel's cautionary diatribe on Remodeling. 
I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US. 
Spray foam is available in two different types: open-cell spray foam which is usually $0.44 to $0.65 per board foot and closed-cell spray foam which is about $1 to $1.50 per board foot. The average cost to have spray foam professionally installed is about $2,314. This number can vary depending on whether the home being insulated is newly constructed. However, finished homes are not a good candidate for spray foam insulation but great for weatherization or an energy audit.  
Installing spray foam is easy to do and can dramatically improve a building or home’s energy efficiency and thermal resistance. Our closed cell foam is so efficient just 3 inches of foam appled inside of wall cavities provides an insulation value of over R18!. Our products are specially formulated for both new construction and existing homes and buildings.
Henry 287 Solar-Flex White Roof Coating is a Henry 287 Solar-Flex White Roof Coating is a premium elastomeric water-based acrylic latex coating designed to reflect the sun's heat and UV rays. Properly applied it is highly resistant to disbonding chalking mildew and discoloration. Expands and contracts with your roof to protect it from leaks aging mold mildew and ...  More + Product Details Close
c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .

How Much Is Spray Foam


Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14]

Spray Foam Hot Roof


This stuff works GREAT ! I live in an older mobile home that had a lot of leaks when I moved-in. I worked for two years to locate and fix them all. Now I simply go over all of the repaired places once a year just to be sure everything is OK. NO LEAKS FOR 4 YEARS NOW!!  Others here use "sno proof" or something that does not stop leaks. When I tell them about my success, they don't seem to want to pay the$ for this superior product. Too bad!. I used the tape in  repairing the leaks.

I live in Baton Rouge LA with a very old and drafty house. There is no blockages in the walls between the crawl space and attic. Lots of critters just come on in. I would like to used closed cell sprayed under house to warm up floors and block moisture. I would like to spray closed cell into attic, but am afraid of enclosing attic due to moisture build-up. Can I spray closed cell against the attic floor in same way as installing bats, thus leaving my venting the same as it always has been. Other ideas? Thanks. https://www.youtube.com/v/ggLAUsiuI_o?version=3
Medium-density foam is applied as low or high-pressure two-component polyurethane spray foam. Medium-density foam offers specific benefits depending on the climate and the type of building in which it is used. Like low-density foam, medium-density SPF is often used for continuous insulation, interior wall cavity fill, and unvented attic applications. However, medium-density is a closed-cell spray foam; it is often used where there is need for the greatest R-value insulation per inch possible. Medium-density foam acts as an air, vapor, and water barrier, and can even help reduce noise.
Current guidelines recommend up to 10 inches of insulation in your attic . This is usually added to the ground, rather than the roof line, which results in the loss of your storage area, due to not being able to refit floor boards after installation. By implementing spray foam insulation to the roof line, you regain the lost 10 inches, thus increasing storage, height and practicality. 

Spray Foam Insulation


Roof coatings can add 25 years to the service life of a roof and reduce the amount of discarded roofing materials that end up in landfills. The infrared image on the right shows 175 °F (79 °C) on the uncoated (black) section of the modified bitumen roof. The coated (white) section is 79 °F (26 °C). Field studies have shown that cool roof coatings can lower rooftop temperatures and reduce air conditioning bills.
Due to its relatively large cell structure, low-density foam stays somewhat soft and flexible after curing. This increases the likelihood of its continuing to provide high insulation value even as the building settles and shifts over time. Low-density SPF provides heat insulation and seals airflow through cracks, joints and seams by filling the cavities. In addition, this foam can help absorb sound thanks to its soft texture and open-cell structure.
Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14]

Spray Foam Hot Roof


Access Panels Adhesives, Backer Rod, Brads, Butyl Rubber, Caulk & Sealants, Caulk Guns, Caulking Gun Accessories, Caulk Gun, Bulk, Chem Curbs, Chinking, Coil Roofing Nails, Concrete Anchors, Concrete Products, Concrete Repair, Concrete Stain & Sealer, Confined Space Rescue, Deck Coatings, Deck Hardware, Diamond Saw Blades, Drains, Drains-Balcony>Drain-Balcony, Drain Downspouts / Nozzles, Roof Drain Domes, Drains New-Roof, Drains-Retrofit / Reroof, Electric Hot Air Welders, Electric Service Flashings, EPDM Accessories, Eternabond, Expansion Joints, Fall Protection Kits, Fasteners, Fire Stopping Vents, Flashing Tape, Foam Roofing, Gas & Safety Cans, Generators, Grouts, Hidden, Deck Fasteners, Hot Dipped Roofing Nails, Hot Tar Kettles, Houseboat Roof/Deck Repair, Knowledgebase, Log Home Products, Lead Pipe Flashings, Lead Sheet, Lifelines- Retractables, Magnetic Hammers, Metal Roofing, Miami-Dade Nails, Mortars, Narrow Crown Stainless, Staples, NP1, Polyurethane Foam, Pipe Flashings, Pipe Supports, Power Tools & Accessories, Propane Hot Air Welders, Propane Regulators, Propane Torches, PVC Roofing, Retrofit Pipe Flashings, Rex Synfelt, Rigging/Lifting Hardware, Rivets, Rivets- Stainless, Roof Anchors, Roof Equipment Hatch, Roof Smoke Vents, Roof Hatch, Roof Leak Repair, Roof Paints & Coatings, Roof Repair Materials, Roof Screws, Roofing Fasteners, Roofing Nails, Rooftop Electrical Flashings, Rope, RV & Trailer Roof Repair, RV Roof Replacement, Safety Rail Systems, Saw Blades, Sealants, Sealing Washers, Snow Guards, Spray Polyurethane Foam, Stinger, Stainless Nails/Fasteners, Tarps, TPO Accessories, Underlayments, Vents, Roof Vents, Video Movies, Waterproofing Products, Window Flashing Tape, Wood Deck Hardware, Zinc Sheet
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

Roof Coating Denver Colorado

×