This website uses cookies and other tracking technologies (also known as pixels or beacons) to aid your experience (such as viewing videos), as well as “performance cookies” to analyze your use of this website and to assist with marketing efforts. If you click the “Accept All Cookies” button or continue navigating the website, you agree to having those first and third-party cookies set on your device. If you do not wish to accept cookies from this website, you can choose to not allow cookies from this website by updating your browser preferences. For more information on how we use Cookies, please read our Privacy Policy.
We have a 1950's ranch in Atlanta and are interviewing foam contractors to spray open cell under the roof, with an "ankle wall" out towards the eaves to seal the attic. My wife and daughters are chemically sensitive, so I'm trying to figure out how to minimize the fumes coming into the house. Additionally, at least one contractor has offered (for > $900) to remove our existing rock wool & R-13 fibreglass from the attic floor to "increase cross-ventilation into the attic". Seems to me I can't both minimize fumes AND increase cross-ventilation. They also offered to spray a fire-retardant on for >$600. Would ventilation during installation help any or woud the retardant seal off the foam and help that way? Thanks...
I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.

Elastomeric coatings offer effective and affordable solutions for fixing roof leaks. The coatings can be used to repair any type of roof leak. The elastomeric roof coatings can be used throughout the year because they stretch and contract easily to adjust to winter and summer temperatures. It is usually made using polymeric products such as acrylic alongside white pigments like titanium dioxide. This helps create an opaque and reflexive final product.


c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .

How Much Spray Foam Garage


a) Make sure that your house has been well heated prior to installation because the foam expands at different rates as it hits surfaces with different temperatures. If it is cold outside the sheathing may be much colder than the studs consequently the foam may expand more from the sides of the wall cavity creating air pockets in the wall cavity. This can be minimized by an experienced installer.


When it comes to insulating the house, fiberglass tends to be the common form of insulation. However, after comparing fiberglass and spray foam insulation, it’s shocking how fiberglass tends to be the lesser of the two. Although it has deemed reliable over the years, there are way more benefits to insulating your home with spray foam. One of those benefits includes regulating the temperature of your house.
These coatings are emulsified asphalt and consist of asphalt particles dispersed in water; they utilize clay as the emulsifying component. These coatings also contain many types of organic and/or inorganic fibers and fillers to provide extra strength to the coating. These coatings are available in black, brown, or as a reflective coating when titanium dioxide or aluminum pigments are added.
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.
Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products. https://youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
While coatings may potentially stop minor leaks, the roof should be properly repaired and dried prior to coating application. Coatings may be able to seal pinhole leaks, which are leaks not visible to the naked eye. If the roof is leaking, the roof leak will need to be identified and repaired prior to any recoating; do not expect the coating to find and seal the leaks.

Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14]
The RV roof coating is a sealing, weatherproofing and waterproofing product that is used in recreational vehicles, campers and trailers, to name some. It works effectively in sealing the roof’s membrane from water and moisture that would otherwise build up and cause damage to the roof. When unattended, the buildup can eventually leads to leaks inside the RV, causing so much discomfort to your loved ones.

Spray Foam Polyurethane


Some states, municipalities and utilities have programs. Check with your coatings manufacturer for further information. As a membership benefit, RCMA provides maintains a database of current information on rebates and tax credits for installing reflective roofs. RCMA’s customized search tool can be used to find the most up-to-date listings of reflective roofing financial incentives available.
Clean and free the roof surface of any debris and then dry the surface using a cloth. If you happen to have a current coating on the surface, check for adhesion. Consider removing loose coating, repairing, cleaning and then checking the area. Remember to use Energy Guard without thinning it because it is sold ready for use. Containers should not be left open except for a short period of time. You must also ensure that you check for any existing coating adhesion before opening Energy Guard. For application, you will require a brush preferably a bristle brush (synthetic) or a short nap roller. You can also use a good airless sprayer with a 0.031 or 0.027 tip to apply the coatings at (3000 psi/1gpm). You will also need water for cleaning up when you are done.
In addition, it's difficult for an inexperienced installer to evenly spread the insulation foam over a surface. Miissing spots can leave holes and gaps for cold air to get through. Proceed with this project yourself only if you're doing a small insulation project -- such as installing foam in a crawl space or around your plumbing. Leave larger projects like the attic, basement or garage to the professional insulation contractors. Insulation professionals have the tools, equipment and background knowledge necessary. Moreover, they know how to accurately price insulation, whereas you could inaccurately budget for a DIY project and end up paying significantly more. Don't take the medical, physical or financial risks that come with pursuing this as a DIY project unless you're absolutely certain you have the skills. https://youtube.com/v/ggLAUsiuI_o
I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.
For example, a hybrid solution of spray foam and fiberglass batts or rolls combines the air-sealing and vapor-retarder benefits of foam with the economical thermal performance of fiberglass. Another option might be to install spray foam in places that are hard to reach or seal, such as rim joists, the attic floor, and eaves, and then install fiberglass batts and loose-fill in the in the open areas, greatly reducing any draftiness while helping the project budget. Incorporating spray foam into hybrid solutions enhances the building envelope and seals efficiently at a reasonable cost. 
Foam is very sticky; you'll need to wear disposable coveralls with a hood, and gloves, a face mask, and eye protection. It takes some practice to spray foam evenly and, because it expands so dramatically, to control its depth; 2 inches is all you need to seal the joist cavities. You need a clear area so that you can work without interruption; any pause longer than 30 seconds will clog the nozzle and require putting on a new one. It's also critical that the air temperature stays between 75 and 85 degrees.
Access Panels Adhesives, Backer Rod, Brads, Butyl Rubber, Caulk & Sealants, Caulk Guns, Caulking Gun Accessories, Caulk Gun, Bulk, Chem Curbs, Chinking, Coil Roofing Nails, Concrete Anchors, Concrete Products, Concrete Repair, Concrete Stain & Sealer, Confined Space Rescue, Deck Coatings, Deck Hardware, Diamond Saw Blades, Drains, Drains-Balcony>Drain-Balcony, Drain Downspouts / Nozzles, Roof Drain Domes, Drains New-Roof, Drains-Retrofit / Reroof, Electric Hot Air Welders, Electric Service Flashings, EPDM Accessories, Eternabond, Expansion Joints, Fall Protection Kits, Fasteners, Fire Stopping Vents, Flashing Tape, Foam Roofing, Gas & Safety Cans, Generators, Grouts, Hidden, Deck Fasteners, Hot Dipped Roofing Nails, Hot Tar Kettles, Houseboat Roof/Deck Repair, Knowledgebase, Log Home Products, Lead Pipe Flashings, Lead Sheet, Lifelines- Retractables, Magnetic Hammers, Metal Roofing, Miami-Dade Nails, Mortars, Narrow Crown Stainless, Staples, NP1, Polyurethane Foam, Pipe Flashings, Pipe Supports, Power Tools & Accessories, Propane Hot Air Welders, Propane Regulators, Propane Torches, PVC Roofing, Retrofit Pipe Flashings, Rex Synfelt, Rigging/Lifting Hardware, Rivets, Rivets- Stainless, Roof Anchors, Roof Equipment Hatch, Roof Smoke Vents, Roof Hatch, Roof Leak Repair, Roof Paints & Coatings, Roof Repair Materials, Roof Screws, Roofing Fasteners, Roofing Nails, Rooftop Electrical Flashings, Rope, RV & Trailer Roof Repair, RV Roof Replacement, Safety Rail Systems, Saw Blades, Sealants, Sealing Washers, Snow Guards, Spray Polyurethane Foam, Stinger, Stainless Nails/Fasteners, Tarps, TPO Accessories, Underlayments, Vents, Roof Vents, Video Movies, Waterproofing Products, Window Flashing Tape, Wood Deck Hardware, Zinc Sheet
These coatings are emulsified asphalt and consist of asphalt particles dispersed in water; they utilize clay as the emulsifying component. These coatings also contain many types of organic and/or inorganic fibers and fillers to provide extra strength to the coating. These coatings are available in black, brown, or as a reflective coating when titanium dioxide or aluminum pigments are added.
I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US. 

Spray foam insulation is typically priced by volume, meaning your cost will depend on how much material you need to use to insulate your space, although other factors may influence price as well. In most cases, the cost of spray foam insulation is more than worth it, as it's a once and done upgrade that will not only provide energy savings in your home, but also improve your home's overall comfort.