Acrylic coatings are typically applied in two coats, with the second running perpendicular to the first. 1 gallon per 100 square feet is a good estimate for these coatings, as they do not need to be applied nearly as thick as many other coatings. These coatings can be sprayed or roll-applied. Acrylic coatings generally require a re-coat within 2-3 years of application.
Roof coatings can add 25 years to the service life of a roof and reduce the amount of discarded roofing materials that end up in landfills. The infrared image on the right shows 175 °F (79 °C) on the uncoated (black) section of the modified bitumen roof. The coated (white) section is 79 °F (26 °C). Field studies have shown that cool roof coatings can lower rooftop temperatures and reduce air conditioning bills.
Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces. 
Spray polyurethan foam does effectly prevent all six of these heat transfer methods from occurring. These should be the mechanisms by which you judge insulation, in addition to their R-Value. If you're uncertain about installing spray foam insulation, Energy Star has a map that recommends levels of insulation by R-value and cost-effectiveness in the United States.
Access Panels Adhesives, Backer Rod, Brads, Butyl Rubber, Caulk & Sealants, Caulk Guns, Caulking Gun Accessories, Caulk Gun, Bulk, Chem Curbs, Chinking, Coil Roofing Nails, Concrete Anchors, Concrete Products, Concrete Repair, Concrete Stain & Sealer, Confined Space Rescue, Deck Coatings, Deck Hardware, Diamond Saw Blades, Drains, Drains-Balcony>Drain-Balcony, Drain Downspouts / Nozzles, Roof Drain Domes, Drains New-Roof, Drains-Retrofit / Reroof, Electric Hot Air Welders, Electric Service Flashings, EPDM Accessories, Eternabond, Expansion Joints, Fall Protection Kits, Fasteners, Fire Stopping Vents, Flashing Tape, Foam Roofing, Gas & Safety Cans, Generators, Grouts, Hidden, Deck Fasteners, Hot Dipped Roofing Nails, Hot Tar Kettles, Houseboat Roof/Deck Repair, Knowledgebase, Log Home Products, Lead Pipe Flashings, Lead Sheet, Lifelines- Retractables, Magnetic Hammers, Metal Roofing, Miami-Dade Nails, Mortars, Narrow Crown Stainless, Staples, NP1, Polyurethane Foam, Pipe Flashings, Pipe Supports, Power Tools & Accessories, Propane Hot Air Welders, Propane Regulators, Propane Torches, PVC Roofing, Retrofit Pipe Flashings, Rex Synfelt, Rigging/Lifting Hardware, Rivets, Rivets- Stainless, Roof Anchors, Roof Equipment Hatch, Roof Smoke Vents, Roof Hatch, Roof Leak Repair, Roof Paints & Coatings, Roof Repair Materials, Roof Screws, Roofing Fasteners, Roofing Nails, Rooftop Electrical Flashings, Rope, RV & Trailer Roof Repair, RV Roof Replacement, Safety Rail Systems, Saw Blades, Sealants, Sealing Washers, Snow Guards, Spray Polyurethane Foam, Stinger, Stainless Nails/Fasteners, Tarps, TPO Accessories, Underlayments, Vents, Roof Vents, Video Movies, Waterproofing Products, Window Flashing Tape, Wood Deck Hardware, Zinc Sheet

According to the Department of Energy, an estimated 20 to 40 percent of a home’s utility bill could be going to waste from drafts and air leaks around openings. As temperatures cool and energy costs rise, the positive impact of energy efficiency on a building comes into focus. Air can enter and escape a structure through every gap, compromising the building envelope. Adding the right insulation and air-sealing will close these gaps, keeping interior spaces comfortable and reducing energy bills. 

Spray Foam Walls


Spray foam’s thermal performance and advanced air and moisture control can be optimized by combining it with other insulation products like fiberglass batts or rolls, maximizing budget and meeting energy efficiency goals. Combining insulation products creates a custom solution by leveraging the functions of multiple materials to find the best mix for the project. 

Acrylic coatings are typically applied in two coats, with the second running perpendicular to the first. 1 gallon per 100 square feet is a good estimate for these coatings, as they do not need to be applied nearly as thick as many other coatings. These coatings can be sprayed or roll-applied. Acrylic coatings generally require a re-coat within 2-3 years of application.
Prices, promotions, styles, and availability may vary. Our local stores do not honor online pricing. Prices and availability of products and services are subject to change without notice. Errors will be corrected where discovered, and Lowe's reserves the right to revoke any stated offer and to correct any errors, inaccuracies or omissions including after an order has been submitted. http://www.youtube.com/embed/ggLAUsiuI_o
Henry 287 Solar-Flex White Roof Coating is a Henry 287 Solar-Flex White Roof Coating is a premium elastomeric water-based acrylic latex coating designed to reflect the sun's heat and UV rays. Properly applied it is highly resistant to disbonding chalking mildew and discoloration. Expands and contracts with your roof to protect it from leaks aging mold mildew and ...  More + Product Details Close http://www.youtube.com/v/ggLAUsiuI_o&feature=youtu.be
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)
Installations present a number of considerations and recommendations in order to provide a safe environment for application and to avoid overexposure through inhalation. Appropriate ventilation and protective gear is required when applying insulating foam sealant. Installers should wear protective gear, often referred to as “personal protective equipment” (PPE), such as protective clothing, gloves, and eye protection. Direct skin contact should be avoided, and recommendations by the product manufacturer should be followed.
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)
Henry 287 Solar-Flex White Roof Coating is a Henry 287 Solar-Flex White Roof Coating is a premium elastomeric water-based acrylic latex coating designed to reflect the sun's heat and UV rays. Properly applied it is highly resistant to disbonding chalking mildew and discoloration. Expands and contracts with your roof to protect it from leaks aging mold mildew and ...  More + Product Details Close http://www.youtube.com/v/ggLAUsiuI_o&feature=youtu.be
I recently did a remodel project for my basement using spray foam insulation. The original builder has used fiberglass, but I wanted the best insulation i could find. We chose closed cell foam because it blocks moisture from getting into the house. It took one day to install and was fumey for about 3 hours. It was pretty cool watching it being done. It comes out as a liquid and then expands rapidly into a foam. It's quick! Then they took a types of saw to shave it flat with the wall studs so we could then go ahead and drywall.
Low-density foam is applied as low or high-pressure, two-component polyurethane spray foam. Low-density spray foam can be applied on walls, in unvented attics, to ducts and ceilings, and in vented attics and crawl spaces. It is known as an air barrier, but permeable to vapor and moisture. It is often used to fill cavities in walls during construction. http://youtube.com/watch?v=ggLAUsiuI_o&app=desktop
Foam is very sticky; you'll need to wear disposable coveralls with a hood, and gloves, a face mask, and eye protection. It takes some practice to spray foam evenly and, because it expands so dramatically, to control its depth; 2 inches is all you need to seal the joist cavities. You need a clear area so that you can work without interruption; any pause longer than 30 seconds will clog the nozzle and require putting on a new one. It's also critical that the air temperature stays between 75 and 85 degrees.

This website uses cookies and other tracking technologies (also known as pixels or beacons) to aid your experience (such as viewing videos), as well as “performance cookies” to analyze your use of this website and to assist with marketing efforts. If you click the “Accept All Cookies” button or continue navigating the website, you agree to having those first and third-party cookies set on your device. If you do not wish to accept cookies from this website, you can choose to not allow cookies from this website by updating your browser preferences. For more information on how we use Cookies, please read our Privacy Policy.
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

If you haven’t considered spray foam insulation, now may be the time to start looking into it. As you know, having proper insulation will help reduce your heat and air conditioning bills. In specific, spray foam insulation can be particularly helpful during renovations. It can provide a barrier between outside walls, and even a sound barrier for the inside. http://m.youtube.com/watch?v=ggLAUsiuI_o
I live in Baton Rouge LA with a very old and drafty house. There is no blockages in the walls between the crawl space and attic. Lots of critters just come on in. I would like to used closed cell sprayed under house to warm up floors and block moisture. I would like to spray closed cell into attic, but am afraid of enclosing attic due to moisture build-up. Can I spray closed cell against the attic floor in same way as installing bats, thus leaving my venting the same as it always has been. Other ideas? Thanks.
The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.
However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]

Typical roof coating dry film thickness vary from paint film thickness (plus or minus 3 dry mils) to more than 40 dry mils. This means a roof coating actually becomes the top layer of a composite roof membrane and underlying system. As such, the roof coating is the topmost layer of protection for the membrane, receiving the impact of sunlight (both infrared and ultraviolet (UV), rain, hail and physical damage.

How Much Is Spray Insulation In Attic


While the R value will vary, most ocSPF products have an R value of around 3.8 per inch. Unlike medium-density closed-cell SPF, ocSPF is not a vapour barrier. When installed at 5.5 inches or more, ocSPF does act as an air barrier. It is often used for interior walls because it provides sound reduction by blocking and absorbing air leakage. It is usually only recommended for indoor applications. https://m.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o

Builders often turn to high-density SPF when high insulation values and strength are needed. As its name implies, this foam has a denser structure than either of the other SPF types. Therefore, it does not expand as much as lower density foams and requires more material to cover and insulate any given space. This spray foam is often an excellent choice for roofing or other exterior insulation because of its seamless, monolithic nature. High-density SPF can also help reduce energy costs significantly over a roof’s lifetime due to its thermal resistance properties. It also offers increased protection against air and water infiltration and strengthens the structure to which it is applied. The bond that SPF forms to the roof can increase a building’s resistance to wind uplift, which can help reduce damage experienced during periods of high wind.

Also, I'm wondering... Is this website is being regularly updated? A local installer (in Oct, 2010) in MA quoted over twice the price you list here. "Open cell alone ~$1.35 per sq ft for R-13. Or a 'hybrid method' using 2inch closed cell for R-13 followed by 1.5inch open cell for R-6. Hybrid is $2.85 per sq foot for R-19 rating". Maybe installers are charging higher prices to profit from those trying to meet government energy rebate by Dec 31?
I'm in the process of redoing my basement and read through the posts. I took out one inch styrofoam covered by 1/4 " beadboard and installed 2X4s and plan on putting in fiberglass batts between them(r-13) with 1/2 in drywall over top of that. Do you think I will see a significat increase in heat control? Should I have done more?... it's a little after the fact, but still curious to know if I will see a big difference based on your experience.
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.

How Much To Spray Foam Basement

×