Spray Foam Insulation is simply the best insulation you can install in your home or building in Texas. It is estimated that up to 40% or more of your home's energy loss is due to air leakage through holes, cracks and gaps in the building structure. SPF can seal your home from air and moisture leakage, save on costly utility bills, strengthen your home, and help to protect your family's health from dangerous mold and airborne pollutants.


United Coatings™ Roof Coat Elastomeric Coating is an effective coating for providing long-term reflectivity over a wide range of roofing substrates. The high reflectivity of Roof Coat Elastomeric Coating keeps the roof substrate cool, which not only helps prolong its longevity but also helps save on energy costs. Roof Coat Elastomeric Coating’s rich consistency uniformly covers the textured profile of various substrates, forming a flexible monolithic membrane that provides protection from normal weathering, aging, and ultraviolet exposure.
NovaTuff PC-425 An Epoxy Protection Coating, similar to NovaTuff PC-450 but with enhanced flexibility and adhesion. Waterproofing grade. Formulated for continuous underwater submersion and for waterproofing pools, ponds, fountains, tanks, waterfalls etc. Mini-fiber additive aides in bonding/adhesion to difficult surfaces. Excellent chemical and abrasion resistance. Resistant to acids, solvents, caustics, hydrocarbons, salt water, etc. Use submerged or above grade.

Spray Foam Insulation Cost


Sporadic cases of hypersensitivity pneumonitis (HP) have also been reported in workers exposed to isocyanates. The symptoms may seem like the flu, with fever, muscle aches, and headaches. Other symptoms may include a dry cough, chest tightness, and difficult breathing. Individuals with chronic HP often experience progressively more difficult breathing, fatigue, and weight loss. Individuals with acute HP typically develop symptoms 4–6 hours after exposure.[4]

Spray Foam Under House


Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. https://www.youtube.com/attribution_link?a=ggLAUsiuI_o&u=watch?v=XXXXXX&feature=share

Polyurethane is a closed-cell foam insulation material that initially contains a low-conductivity gas in its cells.[5] As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch.[5] In comparison, blown fiberglass typically has an R-Value of only R-3 to R-4 per inch.[6]


Here's a simpler, less expensive alternative: Cut some 2-inch-thick rigid-foam insulation and glue it to the subfloor between the joists or support it with nails driven partway into the joists. Then fill any gaps between the edges of the foam boards and the joists using the canned spray foam sold at home centers or hardware stores. An even easier option is to nail the foam panels against the bottom edge of the joists and seal the joints with canned foam, but you'll lose some headroom and access to any pipes and wires between the joists. As with spray-foam kits, protect yourself and the floor from the dripping globs of canned foam. A full face shield, gloves, and a hat would be a good start.
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.
Sta-Kool 800 15-year White Elastomeric Roof Coating is Sta-Kool 800 15-year White Elastomeric Roof Coating is a high quality very flexible white acrylic latex roof coating. Coverage is 50-75 sq. ft. per gallon per coat. Two coatings are recommended. This performance product resists cracking and peeling while offering tremendous durability. This long lasting formula forms and excellent highly ...  More + Product Details Close

Spray Foam Garage


c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .

How Much Is Spray Foam


Whether you’re sending something fragile in the mail or keeping valuables safe during a move, secure packing is everything. To protect a delicate item, simply fill a spare shopping bag half-full with spray insulation foam and place in the bottom of a box, pressing the item gently into the bag as it hardens to cushion the item. Repeat for the top and you have a DIY custom packaging solution that can handle the rigors of delivery.
Henry 287 Solar-Flex White Roof Coating is a Henry 287 Solar-Flex White Roof Coating is a premium elastomeric water-based acrylic latex coating designed to reflect the sun's heat and UV rays. Properly applied it is highly resistant to disbonding chalking mildew and discoloration. Expands and contracts with your roof to protect it from leaks aging mold mildew and ...  More + Product Details Close
In the case you have above the installer wasn't reading his foam. They must be trained to do that as they spray. Temps and conditions are constantly changing thru out the day. Either he wasn't properly trained or if he was,he wasn't doing his job! This is a serious problem with people jumping in to the foam business. A lot of homeowners and builders are looking the best price and end up with someone who doesn't know what they are doing. Hope this info helps. Foam insulation is a great product. It just has to be done right by someone who knows what they are doing.
Check with the coating manufacturer who may be able to suggest applicators who have used their products and have familiarity with the application. Another option would be to interview contractors and ask specific questions about their proven ability to install roof coatings. Contractors affiliated with the National Roofing Contractors Association (NRCA) or local roofing contractor trade associations typically are more knowledgeable. Consult those groups’ websites for contractors.
Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating is a high quality flexible white acrylic roof coating. Product is enhanced with silicone for improved water resistance adhesion and life expectancy. Product resists cracking peeling while offering tremendous durability and long term life. The coating forms a durable protective barrier which ...  More + Product Details Close http://www.youtube.com/v/ggLAUsiuI_o
Due to its relatively large cell structure, low-density foam stays somewhat soft and flexible after curing. This increases the likelihood of its continuing to provide high insulation value even as the building settles and shifts over time. Low-density SPF provides heat insulation and seals airflow through cracks, joints and seams by filling the cavities. In addition, this foam can help absorb sound thanks to its soft texture and open-cell structure.

How Much Is Open Cell Spray Foam Insulation


I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).

Spray Foam Roofing


NovaTuff PC-425 An Epoxy Protection Coating, similar to NovaTuff PC-450 but with enhanced flexibility and adhesion. Waterproofing grade. Formulated for continuous underwater submersion and for waterproofing pools, ponds, fountains, tanks, waterfalls etc. Mini-fiber additive aides in bonding/adhesion to difficult surfaces. Excellent chemical and abrasion resistance. Resistant to acids, solvents, caustics, hydrocarbons, salt water, etc. Use submerged or above grade.
Spray Foam Insulation is simply the best insulation you can install in your home or building in Texas. It is estimated that up to 40% or more of your home's energy loss is due to air leakage through holes, cracks and gaps in the building structure. SPF can seal your home from air and moisture leakage, save on costly utility bills, strengthen your home, and help to protect your family's health from dangerous mold and airborne pollutants.
Roof coatings made with acrylics, urethanes or asphalt soften under the stress of ponding water or snowpack. Eventually, these roof coatings will bubble and peel away from the substrate, leaving your roof vulnerable to leaks, rot, and decay. However, GacoRoof’s 100% silicone formulation is designed to stand up to whatever the elements dish out. Silicone will withstand areas of ponding water without softening, bubbling or peeling from the substrate. Acrylic, urethane and asphalt roof coatings decompose and wear away from the stress of harsh sunlight, UV rays, and freeze-thaw cycles.
Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable.

Check with the coating manufacturer who may be able to suggest applicators who have used their products and have familiarity with the application. Another option would be to interview contractors and ask specific questions about their proven ability to install roof coatings. Contractors affiliated with the National Roofing Contractors Association (NRCA) or local roofing contractor trade associations typically are more knowledgeable. Consult those groups’ websites for contractors.

Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams.

We have a 1950's ranch in Atlanta and are interviewing foam contractors to spray open cell under the roof, with an "ankle wall" out towards the eaves to seal the attic. My wife and daughters are chemically sensitive, so I'm trying to figure out how to minimize the fumes coming into the house. Additionally, at least one contractor has offered (for > $900) to remove our existing rock wool & R-13 fibreglass from the attic floor to "increase cross-ventilation into the attic". Seems to me I can't both minimize fumes AND increase cross-ventilation. They also offered to spray a fire-retardant on for >$600. Would ventilation during installation help any or woud the retardant seal off the foam and help that way? Thanks... https://www.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o


Amanda previously has worked as a breaking news and crime reporter, TV news producer, and editor in Flint and Detroit. Throughout her career as a journalist, she has won several awards from the Detroit Chapter of Society of Professional Journalists and the Michigan Press Association. As part of the RetroFoam of Michigan family, Amanda uses her experience as a journalist to write content that will help educate homeowners on the benefits of foam insulation. When Amanda isn’t writing, she’s spending time with her husband and rescued huskies. She also loves knitting, making art, cooking, and hosting dinner and a movie night for friends and family.
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

Roof Coating Denver Colorado

×